KingClima KC116Z12 12v Electric Air Conditioner Compressor
Model No:
KingClima KC116Z12
Refrigerant:
R134a
Rated Voltage:
12V DC
Speed:
1800~4000rpm
We're here to help: Easy ways to get the answers you need.
Categories
Relate Product
Product Tags
KingClima is a manufacturer of electric compressors. Our low voltage electric truck ac compressors are used in aftermarket. This is KingClima KC116Z12 12v air conditioner compressor.
Technical of KingClima KC116Z12 12v Electric Air Conditioner Compressor
1. Main Specification
| KingClima KC116Z12 | ||
|
Application
|
EV Air-conditioner System
|
|
|
Compressor Type
|
Rotary DC Timing Compressor
|
|
|
Refrigeration
|
R134a
|
|
|
Oil Trademark·Oil Charge
|
RB68EP&RL68ER¡300ml
|
|
|
Net Weight(Oil Included)
|
7.8 Kg
|
|
|
Displacement
|
11.6 cc/rev
|
|
|
Bindiny Mechanism
|
Suction Connection)
|
7/8 ″threaded
|
|
Discharge Connection
|
5/8 ″threaded
|
|
|
Motor
|
Motor Type
|
Fluorine resistant three-phase Rare-earth
Synchromotor
|
|
Pole
|
8 Pole
|
|
|
Insulation Grade
|
B
|
|
|
Winding Resistance(at 20℃)
|
UV=VW=WU=0.005Ω
|
|
|
Range of rotate speed
|
1800~4000 rpm
|
|
|
Driver
|
Drived by
|
Square wave
|
|
Rated Voltage
|
DC 12V
|
|
|
Running Voltage Range
|
DC 9.5~16V
|
|
2. Characteristic Parameter
2.1 Performance Parameter
|
Item
|
Unit
|
Target Value
|
Remark
|
|
Cooling Capacity
|
W
|
1800
|
≥95%
|
|
Input Power
|
W
|
635
|
≤105%
|
|
Current
|
A
|
53
|
≤105%
|
|
COP
|
W / W
|
2.8
|
Average Value
|
|
Noise
|
dB(A)
|
dB(A)
|
SPL
|
|
Vibration
|
m/s2
|
≤ 10
|
Tangential oscillation
acceleration
|
|
Test Condition
|
|||
|
Power
|
DC 12V
|
||
|
Condensing Temperature
|
54.4℃
|
||
|
Evaporating Temperature
|
7.2℃
|
||
|
Suction Gas Temperature
|
35℃
|
||
|
Degree of Super-cooling
|
46.1℃
|
||
|
Ambient Temperature
|
35℃
|
||
|
Revolution
|
4000r/min
|
||
2.2 Application Scope
| KingClima KC116Z12 | |
|
Range of Ambient Temperature
|
-5~50℃
|
|
Range of Evaporating Temperature
|
-10~15℃
|
|
Range of Condensing Temperature
|
30~65℃
|
|
The Max. Filling Amount of Refrigerant
|
≤800g
|
|
Starting Type
|
DC Inverter Starting
|
|
Demagnetization amps
|
100 A
|
2.3 other Characteristics
|
Item
|
Unit
|
Criterion
|
|
Leakage Testing Pressure
|
MPa
|
2.9
|
|
Destroy Pressure
|
MPa
|
10.5
|
|
Insulating property
|
MΩ
|
When powered with 500VAC, insulation
resistance>50MΩ(Ambient temperature
20℃)
|
|
Withstand voltage
|
no abnormal when powered with500VAC
for one minutes
|
|
|
Residual Moisture
|
mg
|
≤100
|
|
Residual Impurity
|
mg
|
≤35
|